Industrial Alternators Supplier in UAE
Arrowad International Trading supplies industrial alternators in the UAE, including Leroy Somer and Stamford ranges for diesel generator applications across different kVA ratings and operating frequencies. Based in Jebel Ali Free Zone, Dubai, we support customers building, replacing or maintaining diesel generator sets across the UAE and international markets.
If you already know the required brand and rating, explore the dedicated alternator ranges below. If you are still determining the correct specification, this page can help you identify the key requirements before requesting a quotation.
Quick Quote Details
- Required kVA
- Frequency: 50 Hz or 60 Hz
- Duty type: Prime or standby
- Brand: Leroy Somer or Stamford
- Engine make and model
Request an Alternator Quote
Share your required kVA, frequency, duty type and engine information with the Arrowad team. We can review your requirements and identify a suitable alternator configuration for your diesel generator application.
Industrial Alternators for Diesel Generator Applications
An alternator converts mechanical rotation from a diesel engine into electrical power within a generator set. Selecting the correct alternator involves more than matching a kVA number. Frequency, prime or standby duty, engine compatibility, load requirements and generator configuration can all affect the right selection.
Arrowad supplies alternators across a range stated on our site as approximately 9 kVA to 3,000 kVA. Actual ratings vary according to manufacturer and model, so this should be considered a general range rather than a fixed rating applicable to every alternator.
Alternator Brands We Supply
Leroy Somer Alternators
Leroy Somer alternators are available across a wide model range, from smaller generator applications to high-capacity systems. Individual model information includes frequency, prime power and standby power ratings.
Stamford Alternators
Stamford alternators are available for diesel generator applications where the brand is preferred, specified or required by a project’s engineering requirements.
Alternator Power Range
Alternator sizing depends on the electrical load that the generator set needs to support. Starting current, transient loads, operating conditions and future capacity requirements should also be considered when selecting the appropriate rating.
Arrowad’s available alternator range is approximately 9 kVA to 3,000 kVA, depending on manufacturer and individual model. For an accurate selection, share your required kVA or load details with our team.
50 Hz and 60 Hz Alternators
Operating frequency is an important specification when selecting an alternator. The alternator must be suitable for the electrical system and destination market.
50 Hz Alternators
50 Hz is commonly used across the UAE, Middle East, Europe, Asia and Africa.
60 Hz Alternators
60 Hz is commonly used in North America, parts of Latin America and other international markets.
Prime and Standby Power Ratings
Prime Power
Prime power is intended for applications where the generator is used as the primary source of electricity, including off-grid locations and sites with limited or unreliable utility-grid access.
Standby Power
Standby power is intended for backup applications during utility outages. Standby-rated equipment should be operated according to the manufacturer’s specified conditions and duty limitations.
Alternators for Diesel Generator Sets
Alternator selection should be considered together with the engine and complete generator-set configuration. The alternator needs to be appropriately matched to the engine output, operating frequency, voltage and intended application.
Arrowad also builds custom diesel generator sets combining engines such as Cummins and Perkins with Leroy Somer and Stamford alternators.
How to Choose the Right Alternator
- Required kVA: Generator or alternator output requirement.
- Frequency: 50 Hz or 60 Hz.
- Duty type: Prime or standby.
- Preferred brand: Leroy Somer, Stamford or either.
- Engine make and model: Important when replacing an alternator or matching an existing diesel engine.
Industrial Alternator Applications
Industrial alternators can be supplied as part of diesel generator systems for a range of commercial, industrial and power-generation requirements.
- Industrial facilities
- Commercial buildings
- Construction sites
- Standby and backup power systems
- Prime power installations
- Off-grid and limited-grid locations
Why Choose Arrowad for Industrial Alternators?
- Based in Jebel Ali Free Zone, Dubai, serving UAE and international customers.
- Supply of Leroy Somer and Stamford alternator ranges with model-level specifications and datasheets.
- Products supplied with certificates of origin.
- Custom diesel generator sets using compatible Cummins and Perkins engines.
- Access to genuine spare parts.
- Related products include Yuchai G-Drive engines, generator accessories, generator controllers and generator batteries.
Frequently Asked Questions About Industrial Alternators
What alternators does Arrowad supply?
Arrowad supplies Leroy Somer and Stamford alternators for diesel generator applications, with models available across different power ratings and 50 Hz and 60 Hz configurations.
What size alternators does Arrowad supply?
Arrowad’s stated alternator range is approximately 9 kVA to 3,000 kVA. Exact ratings and availability depend on the manufacturer and individual model.
Does Arrowad supply Leroy Somer alternators?
Yes. Arrowad supplies a dedicated range of Leroy Somer alternators with model-specific information and datasheets.
Does Arrowad supply Stamford alternators?
Yes. Stamford is one of the two alternator brands supplied by Arrowad for diesel generator applications.
Does Arrowad supply industrial alternators in Dubai?
Yes. Arrowad operates from Jebel Ali Free Zone, Dubai and supplies alternators to customers in the UAE and international markets.
What is the difference between prime and standby ratings?
Prime power is intended for primary power use, while standby power is intended for backup use during utility outages.
How do I choose the right alternator?
Start with the required kVA, frequency, duty type and engine make and model. Load characteristics, starting requirements and voltage should also be considered.
Can Arrowad supply a complete generator?
Yes. Arrowad can supply alternators as part of custom diesel generator solutions.
Need an Industrial Alternator?
Share your required kVA, frequency, duty type and engine information with the Arrowad team. We can review your requirements and identify a suitable alternator configuration for your diesel generator application.

